AC Flood Guard GraviTrip™

A gravity-activated shutoff for A/C overflow.

GraviTrip shuts off HVAC equipment when the condensate drain line clogs, backs up and fills the collection bottle. It works on weight, with no float mechanism.

  • 2 issued U.S. patents
  • Factory calibrated trip weight
  • 3-year limited switch warranty
The AC Flood Guard GraviTrip retail box. The side panel shows how it works in three steps.
The GraviTrip kit ships complete with its installation insert.

See how it works

Three steps from overflow to shutoff.

Under normal conditions the bottle stays empty and the system runs as usual. GraviTrip acts only when overflow water has somewhere to go: into the bottle.

  1. Drain-line backflow fills the bottle

    If the condensate line clogs or backs up, overflow runs through 3/4-inch PVC and the L-adaptor into the collection bottle.

  2. Water weight triggers the switch

    At the set fill level, the added weight pulls the factory calibrated chain and physically actuates the weight-activated switch.

  3. 24 V control circuit shuts off the HVAC

    Wired in series on the 24 VAC R lead, the switch opens the control circuit and the system stops running.

The GraviTrip kit in its foam packaging: switch box, bottle hanger, collection bottle, L-type adaptor, chain, chain clip, mounting screws and red and black wire leads.
Everything needed at the unit, in one box.

What's in the box

A complete kit for one installation.

Every part is listed on the packing insert so installers can check the kit before they start.

GraviTrip kit contents
QtyItem
1Switch box assembly with UL 61058-rated switch, UL 94 V-1-rated switch box and wiring leads
1Bottle hanger
1Collection bottle
1L-type adaptor (antimicrobial, to reduce algae buildup)
1Chain assembly (factory calibrated length)
1Chain clip
2Mounting screws
1Pair of 18 AWG UL 1007-rated red and black wire leads
1Instruction and warning insert

Specifications

Built for indoor 24 VAC systems.

Download the insert (PDF, 1.3 MB)
GraviTrip specifications
FunctionShuts off HVAC equipment when the condensate drain line clogs, backflows and fills the collection bottle
ActivationGravity (weight) activated. The switch is factory calibrated to trip at a specified suspended load that includes the full factory chain.
ApplicationIndoor HVAC equipment with a 24 VAC low-voltage control circuit, where permitted by the equipment manufacturer
Control connectionIn series on the 24 VAC R (red) control lead. Not for 120/240 VAC line voltage.
Drain connection3/4-inch PVC, with the L-type adaptor bonded using approved PVC cement
ComponentsUL 61058-rated switch, UL 94 V-1-rated switch box, 18 AWG UL 1007-rated wire leads
MountingTwo mounting screws, into a stable support that holds at least 2.2 lb
ResetEmpty the bottle, refit it, then gently pull the chain
MaintenanceTest the switch and inspect the installation every six months and after any HVAC service. Clean with mild soap and water only.
InstallationProfessional installation only, by a qualified HVAC technician or licensed electrician
Warranty3-year limited warranty, covering switch failure only

A second line of defense

Safety float switches can fail. GraviTrip adds another layer.

Many air handlers rely on a float switch at the condensate line or in the emergency pan. With only 42% of homeowners having a professional service their A/C regularly, drain lines often go uncleaned and float switches go untested.

  1. Regular drain-line maintenance

    A professional cleans the condensate drain line.

  2. Safety float switch

    A float in the drain line or emergency pan rises with the water.

  3. GraviTrip gravity-activated shutoff

    A supplemental shutoff that trips on the weight of overflow water collected in the bottle.

Patented technology

U.S. Patent No. 11,320,172

Air conditioner shut-off system and method to prevent drainage overflow

Filed
Issued
Inventor
David Todd Walker, Jr.
View US 11,320,172 on Google Patents

U.S. Patent No. 11,692,736

Air conditioner shut-off system and method to prevent drainage overflow

Filed
Issued
Inventor
David Todd Walker, Jr.
View US 11,692,736 on Google Patents

Important limitations

GraviTrip is a supplemental safety device, not a leak detector. It does not detect leaks outside the collection path, internal evaporator-pan overflows that aren't routed to the bottle, freezing, power loss, or improper installation. Professional installation only, on indoor 24 VAC low-voltage HVAC control circuits.

Read the full use restrictions and limitations

Add GraviTrip to the systems you service.

Ask about pricing and availability, or work through the installation guide step by step.